Send Studies To A DICOM Device

You can send a study from OmegaAI to a DICOM station, such as a PACS or a modality, through OmegaAI Link. This is also called a DICOM Transmit or DICOM Store Push.

This article shows you how to send a study, what's sent with it, and how to check that the destination station is online.

Before You Begin​

  • Destination: The destination must be an active DICOM station under a Link device, with Send to DICOM Stations turned on in the station's Outbound Send section. Only these stations appear as destinations. See Add and set up a DICOM station.
  • Station online: OmegaAI doesn't try to send to a station that's offline. See How The DICOM Heartbeat Affects Sending.

What's Sent With The Study​

  • Key images: If the study has key images, a Key Object Selection (KO) object is created and sent with the study, so the receiving system can find the key images. KO objects follow the DICOM C.17.6 Key Object Selection standard.
  • Final report: The study's final report is sent as a DICOM-encapsulated PDF, so the destination system can receive and display it.
  • Visit, order, and patient documents: If the destination station has Send Visit Documents or Send Patient Documents turned on in its Outbound Send section, those documents are also sent as encapsulated PDFs.

Send A Study​

  1. In the Worklist, right-click the study. A menu opens.

  2. In the row of icons at the top of the menu, click Send.

    OmegaAI Link

    The Send panel opens. For all send options, see Worklist Send Options.

  3. Click the SEND STUDY tab.

  4. Enter the send details:

FieldRequiredWhat to enter
Send toYesSelect Imaging Organization.
Send MethodRead-onlySet to DICOM Send. You can't change it.
PriorityYesSelect a preconfigured priority. The default is Low.
Imaging OrganizationYesType the name of the imaging organization you're sending to. Matching organizations appear as you type.
Destination (Device)YesSelect the device. Every device associated with the selected imaging organization is listed. You can select only one device.
De-identify StudyNoTurn on to remove patient-identifying information (anonymize the study) before it's sent.

OmegaAI Link

  1. Click SEND STUDY. To discard, click CANCEL.

Expected result: A message confirms that the transmission was successful, and the study is added to the send queue.

Note: To check the progress and status of the transmission, open the Task Log.

Note: If the destination DICOM station has Send New Objects Only turned on in its Outbound Send section, only the objects that station doesn't already hold are sent. Skipped objects are marked Skipped: object already exists on destination. If OmegaAI can't check what the station holds, the whole study is sent. See Send New Objects Only in Add and set up a DICOM station.

How The DICOM Heartbeat Affects Sending​

The DICOM heartbeat keeps OmegaAI from sending studies to a station that's offline.

When the heartbeat is turned on for a station, the station's Link sends it a DICOM echo (C-ECHO) once a minute. The station's status badge shows the result.

StatusIndicatorMeaning
OnlineGreenThe heartbeat is on, and the station answers.
OfflineRedThe heartbeat is on, and the station doesn't answer. OmegaAI doesn't try to send to it.
Not updatedNoneThe heartbeat is off, so the badge isn't kept up to date.

To see a station's status:

  1. In the left navigation bar, click Organization.
  2. Select your organization, and then click Details.
  3. In the settings menu, click Device.
  4. In the Devices list, select the OmegaAI Link that the station is connected to.
  5. In the Stations list, select the station.

Expected result: The status badge appears at the top of the station's General section, next to TEST CONNECTION.

Tip: To check a station right away instead of waiting for the next heartbeat, click TEST CONNECTION. See Query And Retrieve Studies From DICOM Devices.

To turn on the heartbeat, select Enable Heartbeat in the station's DICOM Station Features. See Add and set up a DICOM station.

Troubleshooting​

ProblemWhat to check
The destination device isn't listedCheck that you selected the right imaging organization. Only devices associated with it are listed. Also check that the station is active and has Send to DICOM Stations turned on.
The study isn't sentCheck the station's status. OmegaAI doesn't send to a station that's offline.
The send failedOpen the Task Log and check the task's status. A failed send isn't retried on its own, so retry it from there. After 10 failed tries, the task is rejected.
Only part of the study arrivesThe station may have Send New Objects Only turned on, so objects it already holds aren't sent again.

For more, see Transfers are slow, or studies arrive with missing images.