Coming Soon: Sign Delay
Overviewβ
Sign Delay gives radiologists and reading physicians a brief, configurable window to undo a signed report before it is permanently finalized. Once a report is signed, it enters a Pending Signature state and a countdown begins. When the timer reaches zero, the signature is locked in.
Sign Delay is enabled by default for all organizations β existing and new. To configure: Organization Settings β Details β Workflow Steps (left panel) β Settings (top right toolbar) β Sign Delay β toggle on (to enable) / off (to disable). Delay range: 0.5 β 15 minutes in 0.5-minute increments. Default: 2 minutes.
What's Newβ
1. Pending Signature State After Signingβ
What changed:β
Every report now enters a Pending Signature state immediately after signing. A countdown timer begins using the organization's configured delay duration (default: 2 minutes). The signature is not finalized until the countdown reaches zero or the user selects Sign Now.
Benefit:β
Provides a brief review window before the signature is permanently applied, allowing users to address last-minute changes without disrupting the signing workflow.
2. Pending Signatures Panelβ
What changed:β
A new Pending Signatures panel is accessible via the bell (notification) icon. After signing, the report is pinned at the top of this panel with a live countdown timer and available actions. The panel is accessible from both the Worklist and the Document Viewer.
Benefit:β
Allows users to monitor and manage pending signatures from a central location without reopening individual reports.
3. Undo and Sign Now Actionsβ
What changed:β
Users can select Undo during the delay period to return the report to an editable (unsigned) state. Alternatively, selecting Sign Now bypasses the remaining delay and immediately finalizes the signature. Re-signing after an Undo restarts the full 2-minute countdown from scratch.
Benefit:β
Provides flexibility to either make corrections before finalization or complete signing immediately when no additional review is needed.
4. Administrator Configurationβ
What changed:β
Sign Delay is on by default for all organizations β existing and new. Administrators can configure the delay duration or disable the feature via Organization Settings. The valid range is 0.5 to 15 minutes in 0.5-minute increments.
Benefit:β
Gives organizations full control over the delay duration or the ability to opt out of the feature entirely.
To configure Sign Delay:
- From the OmegaAI home screen, select your organization.
- Go to Details β a panel opens on the left.
- Scroll down to Workflow Steps and click to open it.
- On the toolbar at the top right corner, click the Settings button.
- Locate Sign Delay and toggle it on or off to enable or disable the feature.
- Adjust the delay duration as needed. Valid range: 0.5 β 15 minutes in 0.5-minute increments.
- Save your changes before navigating away.
Important Notesβ
- Sign Delay is enabled by default for all organizations, including existing and new users. No opt-in or configuration required.
- Every report enters the sign delay queue when signed β there are no exceptions.
- Only the user who signed the report can undo or edit it while in a Pending Signature state.
- Other users cannot modify the report during the delay period.
- Once the countdown reaches zero, the signature is permanently finalized.
- The default sign delay duration is 2 minutes.
- Delay values can be configured between 0.5 and 15 minutes in 0.5-minute increments.
- A value of 0 is not permitted as a delay duration. To disable Sign Delay, administrators must turn the feature off via the toggle.
- Re-signing after an Undo restarts the full 2-minute countdown from scratch.
- Selecting Sign Now permanently finalizes the report and removes the Undo option.
- Administrators control feature enablement and duration through Organization Settings.
- User Impact:
- Existing Users: Sign Delay will be active immediately β no action required. After signing any report, users will see the Pending Signatures panel via the bell (notification) icon along with a live countdown banner at the top of the report viewport.
- New Users: Sign Delay will be active as part of the default organization setup.
Where to Find Itβ
Administrators: OmegaAI Home β Select Organization β Details β Workflow Steps β Settings β Sign Delay toggle
End users: Bell (notification) icon β Pending Signatures panel